19, Jalan PJS 3/59,
Taman Sri Manja,
46000 Petaling Jaya,
Selangor, Malaysia.
+603-7783 2257
+603-7783 4316
Previous | 9 / 138 | Next |
Item | Data | ||
APPROVAL | / | ||
Test standard | IEC60947-7-4/UL1059 | ||
Pitch [mm] | 7.62 | ||
Poles | 02-XXP | ||
IEC60947-7-4 Test data | / | ||
Rated voltage [V] | 630 | ||
Rated current [A] | 32 | ||
Rated connection capacity)(solid/stranded [mm2] | 0.5-6.0 | ||
Surge voltage category/pollution degree/material group | III/2/I | ||
Rated impulse voltage [KV] | 6 | ||
Rated torque) [N.m] | 0.5 | ||
UL1059Test data) | UL1059 | ||
Use group) | B | C | D |
Rated voltage) [V] | 300 | / | / |
Rated current [A] | 30 | / | / |
Rated connection capacity) (solid/stranded [AWG] | 26-Oct | ||
Rated torque£© [Lb. in] | 4.43 | ||
General data) | / | ||
Screw) | M3 | ||
Inflammability class)UL94 | V-0 | ||
Ambient temperature) [¡æ] | -40~+105 | ||
Relative humidity) | 5%-95% | ||
Inspection standard£© | MIL-STD-105E II | ||
AQL) | 0.65 | ||
Warranty) | 12 months | ||
Material and plating£© | / | ||
Housing) | PA66 | ||
Screws) | Steel£¬Zn plated | ||
Contact) | Copper alloy£¬Sn plated | ||
Cage) | Steel£¬Zn plated | ||
Wire connecting | |||
13-14mm; Recommended stripping length 13-14mm; | |||
1.£©For solid wire, stripping wire to the appointed length £¬press button and insert the wire. | |||
2.£©For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
Tightening process should be steady, can’t use explosive force.) |
|