DEGSON - DG335W PCB UNIVERSAL SCREW TERMINAL BLOCK

Previous 115 / 138 Next

DEGSON - DG335W PCB UNIVERSAL SCREW TERMINAL BLOCK PCB Universal Screw Terminal Block Terminal Blocks Degson
Quantity
Add Quotation


Item Data        
APPROVAL          
Test standard IEC61984/   UL1059        
Pitch                                                [mm] 5        
Poles 02-12P        
IEC61984  Test data  /        
Rated voltage                                            [V] 250        
Rated current                                          [A] 12        
Rated connection capacity(solid/stranded)              [mm²] 0.2-2.5        
Surge voltage category/pollution degree/material group III/2/I        
Rated impulse voltage                                 [KV] 4        
Rated torque                                          [N.m] 0.5        
UL1059Test data UL   File Number E228872        
Use group B C D    
Rated voltage                                          [V] 300 / 300    
Rated current                                            [A] 16 / 10    
Rated connection capacity (solid/stranded)             [AWG] 28~12        
Rated torque                                         [Lb.   in] 4.43        
General data /        
Screw M3        
Inflammability class UL94 V-0        
Ambient temperature                                  [¡æ] -40~+105        
Relative humidity 5%-95%        
Inspection standard MIL-STD-105E   II        
AQL 0.65        
Warranty 12   months        
Material and plating /        
Housing PA66        
Screws Steel£¬Zn-Ni plated        
Contact Copper   alloy£¬Sn Plated        
Cage Copper   alloy£¬Ni Plated        
Wire   connecting          
Recommended stripping length 5-6mm;          
1.£©For solid   wire, stripping wire to the appointed length, then tightening with rated torque.        
2.£©For stranded   wire: stripping wire to the appointed length, mating with corresponding type   of ferrule, then tightening with rated torque.
Notes: Tightening process should be steady,   can’t use explosive force.        

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  




 
You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Subscribe Newsletter